Performance Study of a 3×1×1 M3 Dual Phase Liquid Argon Time Projection Chamber Exposed to Cosmic Rays
Journal of instrumentation(2021)
摘要
We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m3) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views.
更多查看译文
关键词
Large detector systems for particle and astroparticle physics,Neutrino detectors,Particle tracking detectors,Time projection chambers