Assessment of Systemic Circulation Using Ultrasound Doppler in Late Onset Neonatal Sepsis and Its Clinical Correlation: an Observational Study.
Journal of Ultrasound(2023)
摘要
To measure the Doppler velocimetry parameters in the anterior cerebral artery (ACA), superior mesenteric artery (SMA), and main renal artery (RA) in neonates with late-onset sepsis and correlate it with associated clinical morbidities. Prospective observational study carried out at a tertiary-level neonatal intensive care unit in India in 2022, enrolling 20 neonates with late-onset neonatal sepsis (LONS). Baseline characteristics and sepsis parameters obtained. Serial ultrasound performed on days 1, 3, and 7 from the day of clinical sepsis in the ACA, SMA, and RA and velocimetry measurements obtained. The findings were compared with 20 gestational age (GA) matched neonates in the control arm. The mean GA of neonates with LONS was 31.03 ± 2.79 weeks and their mean birthweight was 1474 ± 509.99 g. The peak systolic velocity, resistive and pulsatility indices were significantly higher in ACA, SMA, and RA and the end-diastolic velocity was significantly lower in ACA and RA (P < 0.05) in LONS. The incidences of intraventricular hemorrhage (IVH), necrotising enterocolitis (NEC), and acute kidney injury (AKI) in neonates with LONS were 45
更多查看译文
关键词
Late-onset sepsis,Ultrasound Doppler,Neonate,Systemic circulation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要