HYDRODYNAMIC ASSESSMENT OF EXPLANTED DEGENERATED TRANSCATHETER HEART VALVES: NOVEL INSIGHTS INTO NON-CALCIFIC VALVE DEGENERATION
КАРДИОЛОГИЯ УЗБЕКИСТАНА(2024)
Abstract
BackgroundThe etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms.ObjectivesThe authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology.MethodsTAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs.ResultsA total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14).ConclusionsTAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.
MoreTranslated text
Key words
KEY WORDS calci fi cation,degeneration and dysfunction,multimodality imaging,TAVR explantation,transcatheter aortic valve replacement
求助PDF
上传PDF
View via Publisher
AI Read Science
Must-Reading Tree
Example

Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined